Unprecedented Portable Power Analyzer
Best Partner for Outdoor Mobile Testing
PA2000MINI Power Analyzer Parameters
Input parameters:
Input parameters | Parameter description | ||
Measurement range | Voltage | 1.5V,3V,6V,10V,15V,30V,60V,100V,150V,300V,600V,1000V | |
Current | Direct input (Crest factor is 3) | ||
5A:10mA、20mA、50mA、100mA、200mA、500mA、1A、2A、5A | |||
Sensor input (Crest factor is 3) | 50mV、100mV、200mV、500mV、1V、2V、5V、10V | ||
Maximum continuous allowable input value | Voltage | Choose the lower value of 2000V peak value and 1300V voltage RMS | |
Current | Direct input | ||
5A:Choose the lower value of 15A peak value and 6.5A RMS | |||
Sensor input | Peak value less than or equal to 4 times of the range; RMS value less than or equal to 2 times of the range | ||
Maximum transient allowable input value (≤ 1s) | Voltage | Choose the lower value of 3000V peak value and 1500V RMS | |
Current | Direct input | ||
5A:Choose the lower value of 22.5A peak value and 10A RMS | |||
Sensor input | Peak value less than or equal to 5 times of the range; RMS value less than or equal to 3 times of the range |
Input impedance | PA2000mini |
Voltage input impedance | Input resistance:2MΩ,input capacitance:10pF |
Current input impedance | Input resistance:100mΩ,Input inductor:0.07μH |
Sensor voltage input impedance | Input resistance:1MΩ,input capacitance:45pF |
Input parameter | PA2000mini |
Input bandwidth | DC,0.1Hz~500KHz |
Sampling rate | 500KS/s |
Maximum continuous common mode voltage | 1000Vrms |
Accuracy:
Frequency range of input signal | PA2000mini | |
Voltage / Current | Power | |
DC | Current direct input:0.05+0.10+20uA Voltage input:0.05+0.10 Sensor:0.05+0.05 | Current direct input:0.05+0.10+20uA* voltage reading Voltage input:0.05+0.10 Sensor:0.05+0.10 |
0.1Hz ≤ f < 30Hz | 0.10 + 0.20 | 0.20 + 0.40 |
30Hz ≤ f < 45Hz | 0.10 + 0.10 | 0.10 + 0.20 |
45Hz ≤ f < 66Hz | 0.05 + 0.05 | 0.05 + 0.05 |
66Hz ≤ f < 1KHz | 0.10 + 0.10 | 0.20 + 0.10 |
1KHz ≤ f < 10KHz | 0.20 + 0.10 | 0.30 + 0.20 |
10KHz ≤ f < 50KHz | 0.30 + 0.10 | 0.30 + 0.20 |
50KHz ≤ f < 100KHz | 2.00 + 0.50 | 2.00 + 1.00 |
100KHz ≤ f < 500KHz | 5.00 + 1.00 | 8.00 + 2.00 |
500KHz ≤ f ≤ 1MHz | 6.00 + 1.00 | 10.00 + 2.00 |
The measurement accuracy of the power analyzer is calculated under the following conditions: Temperature: 23±1℃; Humidity: 30-70% RH; Input signal: sine wave; Common mode voltage: 0V; After preheating, line filter: OFF; λ (Power factor): 1; Crest factor: 3. After preheating for 30 minutes, f = frequency. Data update rate: 500 ms.
Display:
Display Parameter | PA2000mini |
Display | 9 inches color LCD display |
Resolution | 800×480 pixels |
Touch screen | Support for touch screen operation |
Display update rate | Same as the data update rate |
Storage:
Internal SSD capacity | 4G storage capacity supports long-time storage of more than 660 hours (normal) |
USB storage interface | Support for USB storage interface |
Measurement Function/Measurement Condition
Data update rate | Select from 50ms、100ms、250ms、500ms、1s、2s、5s、10s、20s |
Display update rate | Same as the data update rate |
Response time | Same as the data update rate |
Harmonics measurement (PLL synchronous source method)
PA2000mini | ||||
Fundamental frequency of PLL source | Sampling rate(S/s) | Window width relative to FFT data length (fundamental frequency) | Maximum harmonic analysis order | Number of sampling points |
10~20Hz | f×3200 | 3 | 128 | 9600 |
20~40Hz | f×1600 | 6 | 128 | 9600 |
40~55Hz | f×960 | 10 | 128 | 9600 |
55~75Hz | f×800 | 12 | 128 | 9600 |
75~150Hz | f×480 | 20 | 128 | 9600 |
150Hz~440Hz | f×320 | 30 | 128 | 9600 |
440Hz~1.1KHz | f×160 | 60 | 80 | 9600 |
1.1KHz~2.6KHz | f×80 | 120 | 40 | 9600 |
Motor function –analog quantity input parameters
Input mode | Safety BNC, floating, isolation, electrical isolation among A, B, Z of TORQUE and SPEED |
Input impedance | 1MΩ±100kΩ |
Range | 1V、2V、5V、10V、20V |
Cut-off frequency (configurable) | 100Hz,10kHz,50kHz,OFF |
Effective measurement range | ±110% |
Maximum allowable voltage | ±22V |
Maximum common mode voltage | ±42Vpeak |
Number of bits | 16bit |
Sampling rate | 200kHz |
Synchronous source | U1~U6/I1~I6/EXT |
Accuracy | ±(0.05% reading + 0.05% range) |
Temperature drift | ±0.03% range/℃ |
Motor function –pulse frequency input parameters :
Input mode | Safety BNC, floating, isolation, electrical isolation among A, B, Z of TORQUE and SPEED |
Input impedance | 1MΩ±100kΩ |
Frequency range | 1Hz~1MHz |
Input amplitude range | ±22Vpeak |
Maximum common mode voltage | ±42Vpeak |
Effective amplitude | 1V |
Minimum high pulse width | 2.5µS or more |
Accuracy | ±(0.05% reading + 1mHz) |
Waveform sampling data storage function:
Storage items | Voltage waveform, current waveform, computing waveform, FFT computation data, rotational speed, analog quantity of torque, harmonic data, custom function |
Storage modes | Normal, real-time, integration synchronization, conditional trigger |
Data type | Value, waveform, value+waveform |
File type | CSV format, PAD format |
Storage | Internal DOM, U disk |
Integration function:
Mode | The manual, standard, continuous, real-time standard and real-time loop mode can be selected. |
WP± mode | Charging/discharging, electricity purchase/sale |
Timer | Set the timer to stop integration operations automatically. 0000h00m00s~10000h00m00s |
Stop counting | The integration time and value will be maintained and the integration operation will be stopped when the integration time reaches its maximum value (10000 hours) or the integration value reaches the maximum/minimum display integration value (±999999M). |
Accuracy | ±( power or current accuracy + time accuracy ) |
Time accuracy | ± 0.02% of reading |
0.05% power measurement accuracy
PA2000mini is the unique portable power analyzer that can be capable of measuring in the industry. With further optimization for the size and weight, it can still ensure 0.05% power measurement accuracy, which is the best testing partner for outdoor PV on-site acceptance and high-speed railway inverter detection.
On-site acceptance for PV and wind power
Many solar PV power stations and wind power stations are set up in remote mountainous areas or installed on roofs with harsh conditions wherein even the power supply would become an issue. This brings out the need of power analyzers not just with high testing accuracy but also being easy to carry. PA2000mini power analyzer is small in size, with battery, and capable of continuous operation for 3-4 hours, making it ideal for on-site acceptance in the environment of the PV and wind power stations.
High-speed railway inverter detection
With the rapid development of electric vehicles, on-line detection for inverter has become an inevitable trend. ZIT6000 portable inverter detector is thoroughly tempered, which can be moved freely in the distribution box with compact design. It implements high-accuracy and high-bandwidth analysis for mobile testing to satisfy your testing requirements in all aspects.
System integration
PA2000mini power analyzer is committed to providing you with convenient testing experience. It contains the power measurement board card with 4 elements and 0.05% power measurement accuracy as well as motor testing board card, which can complete most of the daily measurement applications with ease. Multiple protocol interfaces are used along with the rack kit, making PA2000mini more convenient for system integration.